TOP > ENGLISH > Actual case example > Search from installation results

Search from installation results

Printed board, bolt and nut, you can heck the film thickness gauge of electricity measurement from the actual case example tailored to the item you want measure

Example of introduction for measuring Copper film thickness of printed circuit board

Customer’s request

・I want to measure the film thickness of Copper to be coated on the substrate)Resin) of printed circuit board
・I would like a thickness of 5 to 20 microns

Electrical resistance type film thickness tester RST-231

【Introduction equipment】
Electrical resistance type film thickness tester RST-231

With a short measurement time(0.7second), simply attaching the probe to the measuring part makes it easy and fast to measure the Copper film thickness quickly.Two ranges are also available (2 to 24 microns) as standard equipment

 
 

Case studies for measuring Zinc plating of bolt nuts

Customer’s request

・Coating on bolt nut, I want a measure the film thickness of Zinc plating
・I would like a thickness 1 to 10 microns

X-ray fluorescence coating thickness tester EX-731

【Introduction equipment】
X-ray fluorescence coating thickness tester EX-731

High precision is possible with X-ray fluorescence coating thickness tester by non-destructive and non-contact

Eddy current type film thickness meter DS-110

【Introduction equipment】
Eddy current type film thickness meter DS-110

By calibrating the eddy current type film thickness gauge using the item measured by fluorescent X-ray measurement. Speedy measurement with an eddy current type film gauge and highly accurate measurement become possible

 

Introduction example of X-ray fluorescence coating thickness tester for the purpose of anti rust plating measurement

Customer’s request

・I would like to non-destructively measure Galvanizing applied to Iron bolts.Previously, it was measured with an Eddy current type film thickness tester.

Our proposal content

・Since the eddy current type film thickness tester greatly affects the difference in conductivity generated by the method of manufacturing the base (Fe), a fluorescent X-ray type film thickness tester is recommended for highly accurate measurement

X-ray fluorescence coating thickness tester EX-731

【Introduction equipment】
X-ray fluorescence coating thickness tester EX-731

X-ray fluorescence coating thickness tester is non-destructive, non-contact, highly accurate measurement possible

 
 

When measurement of decorative plating is aimed Case study of introduction of electrolytic firm thickness gauge of measurement of decorative plating

Customer’s request

・Plating Copper, Nickel and Chromium three layers on the Resin.The plating thickness is very thick, and it cannot be measured with a fluorescent X-ray film thickness tester.Is it possible to measure with other measuring methods?

Our proposal content

・At present, there are two types of measurements for multilayer plating, fluorescent X-ray type electrolytic type蛍光X線式は厚いめっきですとX線が下まで透過せず、測定できない場合があります。電解式膜厚計なら破壊式ではありますが、精度の高い測定が可能です。

Electrolytic formula thickness tester GCT-311

【Introduction equipment】
Electrolytic formula thickness tester GCT-311

Up to 5 layers can be set with one measurement file also, we can measure pure Tin layer and alloy layer separately for Double Nickel and Tri Nickel・Tin plating

 
 

Case study of introduction of Beta-ray film thickness gauge for measurement of coated film

Customers request

・I want measure the thickness of the coating film coated on the Resin until now, the destructive measurement by the fault method was performed, but is there a non-destructive measurement method?

Our proposal content

When measuring coating film, Beta wire type and eddy current type can be measured for possible thickness gauge. If the base is metal, since the ground is non-metal, it can be measured by Beta wire type

Beta-ray type film thickness tester BTC-221

【Introduction equipment】
Beta-ray type film thickness tester BTC-221

Measurement of combination of non-metals on non-metals is possible. Plating can also measure plating of combinations where the atomic number of the substrate and the film are separated by 3 or more

 
 